Description
The VPC HFO Closed-Cell Set is a complete Victory Polymers VPC-HFO spray foam system: the A-Side (VPC-ISO) and the B-Side (VPC-HFO resin), matched and sold together. VPC-HFO uses an EPA-approved, low-GWP HFO blowing agent and delivers a high R-value per inch with a built-in air and vapor barrier for walls, roofs, attics, crawlspaces and foundations.
What’s included
- A-Side: Victory Polymers VPC-ISO, 500 lb drum (SKU 57780)
- B-Side: Victory Polymers VPC-HFO resin (SKU 59365, MPN 100000022)
A-Side specifications: VPC-ISO
- Chemistry: Polymeric MDI (pMDI) isocyanate
- Appearance: Brown liquid
- Viscosity: 180 to 220 cps @ 77°F
- Specific gravity: 1.24 @ 77°F
- Flash point: >388°F (ASTM D93)
- Storage: 50 to 100°F, keep sealed and dry (reacts with moisture)
- Shelf life: 12 months
- Package: 500 lb drum
B-Side and finished foam specifications: VPC-HFO
- Foam type: Closed-cell, HFO blown
- Core density: 2.2 lb/ft³ (ASTM D1622)
- Aged R-value: 7.6 per inch (ASTM C518): 2″ = R-15, 3.5″ = R-26
- Compressive strength: 26.1 psi (ASTM D1621)
- Tensile strength: 32 psi (ASTM D1623)
- Closed-cell content: >90% (ASTM D2856)
- Air permeance: 0.0002 L/s·m² @ 75 Pa (ASTM E2178)
- Water vapor permeance: 0.40 perms @ 2″ (ASTM E96)
- Water absorption: 0.5% by volume (ASTM D2842)
- Fire rating: ASTM E84 Class I (flame spread ≤25, smoke developed ≤450)
- Approvals: NFPA 285, NFPA 286, AC377 Appendix X, UL GREENGUARD Gold, CCRR-0411
- Storage / shelf life: 50 to 80°F, 6 months
Processing
- Mix ratio: 1:1 by volume (A:B)
- Spray pressure: 1,000 to 1,300 psi
- Primary and hose heat: 110 to 130°F
- Drum temperature: 70 to 80°F before use
- Substrate: above 40°F and at least 5°F above dew point
- Pass thickness: 1″ minimum; let the core cool below 100°F before the next pass
- Transfer pumps: 2:1 recommended; never cross the A and B lines
Documents
- VPC-HFO Technical Data Sheet (PDF)
- VPC-ISO A-Side Safety Data Sheet (PDF)
- VPC-HFO B-Side Safety Data Sheet (PDF)
Safety data
Review both SDS before handling. The A-Side contains MDI isocyanate and can cause respiratory and skin sensitization: use a supplied-air respirator when spraying, chemical goggles, chemical-resistant gloves and full skin coverage. Foam must be separated from the interior by an approved thermal barrier.
Ordering and support
Questions about rig setup or coverage? Contact us and our team will help you dial in your system before you order. The Spray Market supplies spray foam contractors with equipment, replacement parts, chemicals and safety gear.