Specification
Typical Physical Properties
Property | Foamsulate 50 | Test |
---|---|---|
R-VALUE | 3.7 @ 1″ | ASTM C 518 |
CORE DENSITY | 0.5 LB / Cubic Foot | ASTM D 1622 |
OPEN CELL CONTENT | > 97% | ASTM D 6226 |
SOUND TRANSMISSION COEFFECIENT | 42 | ASTM E 413 |
WATER VAPOR TRANSMISSION – PERMEANCE | 21 Perms at 1” | ASTM E 96 |
AIR LEAKAGE RATE | < 0.02 (L/s-m2) | ASTM E 283 |
NOISE REDUCTION COEFFICIENT | 0.10 | ASTM C 423 |
TENSILE STRENGTH (PSI) | 5.19 | ASTM D 1623 |
DIMENSIONAL STABILITY | < 5% | ASTM D 2126 |
BUILDING CODE CERTIFICATIONS / FIRE TEST DATA | ||
---|---|---|
EVALUATION SERVICE REPORT | ICC | ESR 3081 |
EVALUATION SERVICE REPORT | ICC – FBC Supplement | Florida Building Code – Building Florida Building Code – Residential |
BUILDING TYPES | Approved | I, II, III, IV, V-B: Nonstructural Insulation material |
FLAME SPREAD | ASTM E84 | Class I < 20 |
SMOKE DEVELOPMENT | ASTM E84 | Class I < 400 |
ASTM E119 | Pass | Non Load-Bearing – 1 Hour Rated – Wall Assembly |
NFPA 259 | Pass: Standard fire test method for evaluation of fire propagation characteristics of exterior non-load bearing wall assemblies containing combustible components. | |
NFPA 285 | Pass: Standard fire test method for evaluation of fire propagation characteristics of exterior non-load bearing wall assemblies containing combustible components. | |
NFPA 286 | Pass: Can be used without a 15-minute thermal barrier when covered with one of the approved intumescent coatings as shown on page 2. | |
NFPA 286 AC377 APPENDIX X | Pass: Complies with the applicable requirements of ICC-ES AC377 Appendix X for use in attics and crawlspaces when covered with one of the approved intumescent coatings as shown on page 2. | |
UL LISTING | FWFX.R38039 | Exterior Wall System Components |
UL LISTING | FWFO.EWS0013 | Exterior Wall Systems |